Smart Home Living: Elevate your with our intelligent WiFi circuit breaker, allowing you to check the usage of all household appliances while offering remote control and scheduling capabilities for a truly smart living experience.
Copper Materials: Crafted from copper for excellent conductivity, a with flame retardant P 6 material that withstands high temperatures, ensuring enhanced in every application.
Versatile Timer Settings: Choose from four convenient timer modes, Scheduled, Countdown, Cycle Timer, and Pulse , so you can set your conditioning or other devices to turn on before you arrive home after a day.
Item Type: Smart Circuit Breaker
Material: P 6
Operating Voltage Range: AC80V-300V (Single Phase)
Rated Frequency: 50 60Hz
Current: 1-63A
Setting Range:
Overvoltage (>U) 120-300V setting range: ( )
Under Voltage (Leakage 10-99Ma shutdown
: (This function can be turned off)>U andOvercurrent and leakage
Time: 1-30 off
Power Display Range: 0- 99.9kwih
Reset Start Delay: 10s-99s
Working Temperature: -30 celsius to 70 celsius
Is this feature availableFunctionYou can set overvoltage, undervoltage, overcurrent leakage current in the application, or set the following parameters in the protector
YesOn off, timed1. Four timing modes: timing mode, countdown mode, timing, and jog (30 sets of timing settings)
YesReclosing gate2. Automatic reclosing APP (onCelsiusoff)
YesMetering3. View the amount of electricity input from photovoltaic power generation to the national grid * The APP can view the amount of electricity input to the national grid by hour, day, month, and year (prepaid function)
YesUnder voltage ( )4. Undervoltage 80V-210V ( ) (default 175V)(This parameter is only set on the app) (OnCelsiusOff)
YesOvervoltage ( )5. Overvoltage 120V-300V ( ) (default 275)(This parameter is only set on the app) (OnCelsiusOff)
YesOvercurrent ( )6. Overcurrent 1.0A-63A (accuracy 0.1A) ( )(Default 63A) (This parameter is only set on the app) (OnCelsiusOff)
YesReclosing time ( )7. Reconnection time (delay time): 10s-99s (default 10s) (this parameter is only set on the app) (onCelsiusoff)
YesRecloser frequency ( )8. Overcurrent leakage time: 1-30 off (default value 5)This feature can be turned off (this parameter is only set on the app)
NoPhotovoltaic bidirectional metering9. View the input power of photovoltaic power generation to the State Grid * The APP can view the hourly, daily, monthly, and annual power generation input to the State Grid
NoLeakage current ( )10. Leakage : 10-99mA (default 50mA), this function can be turned off (this parameter is only set on the app) (onCelsiusoff)
YesTemperature ( )11. Over temperature : 10-85 (this parameter is only set on the app) (onCelsiusoff)
NoOvercurrent delay ( )12. Overcurrent delay ( ) (delay time): 1s-15s (default 1s)(This parameter is only set on the app) (ONCelsiusOFF)