9 in 1 Voltmeter Ammeter 10A 20A 50A 100A Multifunction Digital IPS Voltage Current Power Energy Battery Electricity Test Meter
Barva









Popis
Battery Included : No High-concerned chemical : None Dimensions : Digital Only Output Voltage : DC4~30V Accuracy Class : oltmeter Ammeter Measuring Energy Range : Power Energy Model Number : Voltmeter Max Operating Current : 80A - 99A Power Supply : DC Display Type : Digital Only DIY Supplies : Electrical
Origin : Mainland China
DC4~30V Digital Voltmeter Ammeter Multifunction Tester Electricity Power Meter Wattmeter Energy Frequency Meter 10A/50A/100A
Product features: Supports cumulative data reset and forced zero reset with no load Supports voltage display fine tuning and current display fine tuning Columnar temperature waterproof probe, temperature measurement range -40~120 ℃ High definition IPS LCD color screen with a resolution of 135 * 240 Can simultaneously measure voltage, current, power, percentage, electricity, temperature, cumulative capacity, energy, operating time 10A technical parameters: Instrument working voltage: XH-3P red black wire DC4~30V (do not overvoltage power supply) Introduction to Wire Definition: XH-2.54-3P red black yellow wire (total length of thin wire: 155mm) Thin red wire: the positive pole of the working power supply cannot be connected to a power supply above 30V Thin black wire: The negative pole of the working power supply is grounded together with the thick black wire, and there is no need to connect it when sharing the power supply Thin yellow wire: voltage test wire, connected to the positive pole of the test circuit power supply VH-3.96-2P thick red black wire (total length of thick wire: 165mm) current test wire, parallel shunt resistor of thick wire, cannot be directly connected to the two poles of the power supply, and may cause short circuit Thick red wire: current test positive pole, connected in series at the back end of the negative pole of the load, and connected first and then disconnected when connecting the wire Thick black wire: current test negative pole, connect to the negative pole of the power supply, and connect the broken wire first and then disconnect it Connection diverter: On board low-temperature drift alloy resistance shunt, can be directly connected according to the wiring diagram Voltage measurement range: DC0~100V Error ± 1.00V 0.1V Jump Current measurement range: 0.00A~10.00A Error ± 0.1A 0.03A Jump Power measurement range: 00.00~1000W Capacity measurement range: 0~9999999mAh Energy metering range: 0~9999999mWh Temperature sensor: cylindrical waterproof probe NTC 10K 3950 1% sensor with a total length of approximately 1 meter Temperature measurement range: -40~120 ℃ (external temperature measured by NTC sensor) Time measurement range: 0~999:59:59 (hour: minute: second) Working energy consumption: 20mA (measured at DC12V) Support: Accumulated data reset, no load forced reset, voltage display, fine adjustment, current display, fine adjustment Percentage battery display: Based on voltage reference, the percentage battery (full and low battery voltages need to be manually set) Product size: 47.59 × twenty-eight point six seven × 25.33mm Installation hole: 45 × 26mm 50A technical parameters: Instrument working voltage: XH-3P red black wire DC4~30V (do not overvoltage power supply) Introduction to Wire Definition: XH-2.54-3P red black yellow wire (total length of thin wire: 155mm) Thin red wire: the positive pole of the working power supply cannot be connected to a power supply above 30V Thin black wire: The negative pole of the working power supply is grounded together with the thick black wire, and there is no need to connect it when sharing the power supply Thin yellow wire: voltage test wire, connected to the positive pole of the test circuit power supply VH-3.96-2P thick red black wire (total length of thick wire: 165mm) current test wire, thick wire cannot be directly connected to the two poles of the power supply, which will cause a short circuit Thick red line: current test positive pole, parallel shunt connected to the rear end of the negative pole of the load Thick black wire: current test negative pole, parallel shunt connected to power negative pole Connecting the splitter: A parallel 50A 75mV splitter is required to use (the splitter needs to be provided by oneself) Voltage measurement range: DC0~100V Error ± 1.00V 0.1V Jump Current measurement range: 0.00A~50.00A Error ± 0.5A 0.03A Jump Power measurement range: 00.00~5000W Capacity measurement range: 0~9999999mAh Energy metering range: 0~9999999mWh Temperature sensor: cylindrical waterproof probe NTC 10K 3950 1% sensor with a total length of approximately 1 meter Temperature measurement range: -40~120 ℃ (external temperature measured by NTC sensor) Time measurement range: 0~999:59:59 (hour: minute: second) Working energy consumption: 20mA (measured at DC12V) Support: Accumulated data reset, no load forced reset, voltage display, fine adjustment, current display, fine adjustment Percentage battery display: Based on voltage reference, the percentage battery (full and low battery voltages need to be manually set) Product size: 47.59 × twenty-eight point six seven × 25.33mm Installation hole: 45 × 26mm
100A technical parameters: Instrument working voltage: XH-3P red black wire DC4~30V (do not overvoltage power supply) Introduction to Wire Definition: XH-2.54-3P red black yellow wire (total length of thin wire: 155mm) Thin red wire: the positive pole of the working power supply cannot be connected to a power supply above 30V Thin black wire: The negative pole of the working power supply is grounded together with the thick black wire, and there is no need to connect it when sharing the power supply Thin yellow wire: voltage test wire, connected to the positive pole of the test circuit power supply VH-3.96-2P thick red black wire (total length of thick wire: 165mm) current test wire The parallel shunt resistor with thick wires cannot be directly connected to the two poles of the power supply, which may cause a short circuit Thick red line: current test positive pole, parallel shunt connected to the negative end of the load in series. Thick black wire: current test negative pole, parallel shunt connected to power negative pole. Connecting the splitter: A parallel 100A 75mV splitter is required to use (the splitter needs to be provided by oneself) Voltage measurement range: DC0~100V Error ± 1.00V 0.1V Jump Current measurement range: 0.00A~50.00A Error ± 1A 0.03A Jump Power measurement range: 00.00~9999W Capacity measurement range: 0~9999999mAh Energy metering range: 0~9999999mWh Temperature sensor: cylindrical waterproof probe NTC 10K 3950 1% sensor with a total length of approximately 1 meter Temperature measurement range: -40~120 ℃ (external temperature measured by NTC sensor) Time measurement range: 0~999:59:59 (hour: minute: second) Working energy consumption: 20mA (measured at DC12V) Support: Accumulated data reset, no load forced reset, voltage display, fine adjustment, current display, fine adjustment Percentage battery display: Based on voltage reference, the percentage battery (full and low battery voltages need to be manually set) Product size: 47.59 × twenty-eight point six seven × 25.33mm Installation hole: 45 × 26mm
Shipping list: Measuring instrument X1 Column waterproof probe sensing line X1 XH-2.54-3P red black yellow wire X1 VH-3.96-2P thick red black wire X1



























